dc.description.abstractIn the quest to justify current orthotic treatment protocols, there is a trend for clinical practitioners to invest in computer-assisted video gait analysis systems, and rely less on clinical measurement protocols. The aim of the study was to determine the extent to which an experienced clinician would benefit in obtaining precise and reliable measurements by replacing their inexpensive static measurement protocol with a computer-assisted video analysis system. Measures of 10 subjects, having both a functionally stable and unstable ankle, were obtained in the frontal plane. This was done statically using clinical protocol and dynamically using the Ariel Performance Analysis System (APAS). The static clinical and dynamic laboratory protocols were found to be comparable and of acceptable reliability (ICC > 0.810) and a minor mean improvement in precision (0.23°) was observed when using the laboratory protocol. It was, therefore, concluded that if the purpose of measurement is to obtain precise and reliable frontal plane data, then the static clinical protocol is as useful as the dynamic laboratory protocol.en
dc.description.provenanceApproved for entry into archive by Gemma Siemensma (gemmas@bhs.org.au) on 2012-11-18T23:23:19Z (GMT) No. of bitstreams: 0en
dc.description.provenanceSubmitted by Gemma Siemensma (gemmas@bhs.org.au) on 2012-11-18T23:23:07ZNo. of bitstreams: 0en
dc.description.provenanceMade available in DSpace on 2012-11-18T23:23:19Z (GMT). No. of bitstreams: 0 Previous issue date: 1997en
dc.publisherElseiver.en
dc.titleReliability and precision of a static clinical versus a dynamic laboratory method of measurement of the leg and foot on stable and unstable ankles.en
dc.typeJournal Articleen
dc.type.specifiedArticleen
dc.bibliographicCitation.titleThe Footen
dc.bibliographicCitation.volume7en
dc.bibliographicCitation.issue3en
dc.bibliographicCitation.stpage135en
dc.bibliographicCitation.endpage138en
dc.subject.healththesaurusORTHOTIC TREATMENTen
dc.subject.healththesaurusCOMPUTER ASSISTED VIDEO ANALYSIS SYSTEMen
dc.subject.healththesaurusANKLEen
dc.subject.healththesaurusARIEL PERFORMANCE ANALYSIS SYSTEMen
dc.subject.healththesaurusLABORATORY PROTOCOLen
dc.date.issuedbrowse1997-01-01en
Appears in Collections:Research Output

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.